The MARINER OMNIPURE® system is available in three sizes: Model M2512V, Model M4016V and Model M6025V. The MARINER OMNIPURE system consists of three key components: V-1 sewage tank, processing unit and V-2 effluent tank. These components are provided separately to better fit the smaller installation spaces that can be found aboard these types of vessels.
OMNIPURE® MARINER® Design Standards |
Model
M2512V |
Model
M4016V |
Model
M6025V |
Personnel Complement (Maximum) |
Black Water Only |
25† |
40† |
60† |
Black & Gray Water |
12† |
16† |
25† |
Treatment Ratings (Maximum) |
Treatment Volume: L/day (Gal/Day) |
2960 (781) |
4540 (1199) |
6800 (1796) |
Treatment Flow Rates |
Average: L/min (Gal/min) |
2.11 (0.56) |
3.11 (0.83) |
4.70 (1.25) |
Dimensions & Weights
(Overall Unit Consisting of V-1 Tank, V- Tank, & Process Module) |
Length: mm (inches) |
2797 (110) |
2797 (110) |
2797 (110) |
Width: mm (inches) |
664 (26.25) |
664 (26.25) |
664 (26.25) |
Heigth: mm (inches) |
938 (37) |
1451 (57.25) |
1745 (68.75) |
Weight: kg (pounds) |
305 (762) |
370 (814) |
422 (929) |
Utility Requirements |
Power: KVA |
7.5 |
7.5 |
10 |
Seawater: L/min (G/min) |
56 (15) * |
56 (15) * |
56 (15) * |
* MARINER OMNIPURE units require seawater supply at all times. Values indicated assume no seawater pump option is selected. |
† 100% capacity shown, STDN recommends that actual operation capacities not exceed 90% of maximum capacity. |
The MARINER OMNIPURE system consists of three key components: V-1 sewage tank, processing unit and V-2 effluent tank. These separate components are provided loose as to better fit the various shaped installation spaces that can be found aboard vessels. |
All information is subject to change |
|