Ballast Water Treatment Systems, Wastewater Arsenic Removal, On-site Hypochlorite Generators, Gas Chlorinators, Water & Wastewater Ultraviolet Disinfection Products
Toll Free: 1-866-646-9201   Phone: 1-215-646-9201
The leader in water and wastewater purification products and services
Home About Us Downloads Press Room Contact Us
Products
Services
Brands
Applications

Products Search
 
Chlorine - Hazardous Gas Monitor
  Contact Info:

north america- northeast
& eastern canada
joel neulight
+1(215) 997-4052
send email

north america- southeast
mitch matthews
+1(706) 255-8964
send email

north america- midwest
& middle canada
greg gaffney
+1(281) 240-6770
send email

north america- west
& western canada

bill kelly
+1(408) 309-1549
send email

latin america
carlos osorio
+(571) 677 4559
send email 

middle east/africa
ghazi almani
+202 2703 2005
send email

asia pacific
bill stimeling
+1(215) 997-3754
send email

europe
+44 (0)121 313 2300
send email

u.s. regions map

The Capital Controls® Series 17CA3000 Chloralert™ Plus is a state-of-the-art device for rapidly measuring and alarming the ambient presence of low concentrations of toxic gases. The microprocessor-based receiver can accept in put from up to four independent sensors each designed to accurately determine part per million levels of chlorine or sulfur dioxide. The receiver enclosure is NEMA 4X rated and can be wall mounted wherever the monitored gases are manufactured, stored or utilized. Each gas sensor may be located up to 1000 feet (305 meters) from the receiver. Multiple relays allow for remote alarming and activation of ancillary safety equipment such as blowers, scrubbers, etc.

The series 17CA3000 incorporates a unique one-man calibration procedure that allows one person to calibrate each sensor using the optional CAL2000 Calibrator. This feature allows the person doing the calibration to have instantaneous indication of the progress of the calibration at the sensor location.

The multi-line digital display shows the operating conditions of each of the sensors simultaneously. This includes indication of the actual detected gas levels in either PPM or mg/m3 as well as any operational or concentration alarms.

Configurable concentration alarms for instantaneous, short term exposure limit (STEL) and time weighted average (TWA) to meet various regulatory agency requirements.